New York City door work answers to the 2022 Construction Codes, and the binding rules on locks, egress and fire-rated hardware sit in Chapter 10.

What to take away

  • Doors moved from Section 1008 in the 2014 code to Section 1010 in the 2022 edition. A quote built on an old printout cites a section that no longer exists.
  • Section 1010.1.9 bars a key, tool or special knowledge from the inside face of an egress door. Chain locks and surface bolts fail the same rule.
  • Section 716 sends fire door assemblies to NFPA 80. The door, frame, hinges and lock all carry the rating, and the label has to stay legible.
  • The Housing Maintenance Code puts locks and entrance hardware on the building owner, so the property manager authorizes the work, not the tenant.
  • Fire Code Section 506 key boxes have to hold current keys. A rekey that leaves the box stale is a violation waiting on the next alarm.

What changed in the 2022 codes

New York City writes its own construction codes instead of adopting a model code whole. The 2022 NYC Construction Codes, issued by the Department of Buildings, track the 2021 International Building Code with local amendments. Door and hardware rules sit in the Building Code volume.

Section numbers moved in that edition. Doors were in Section 1008 of the 2014 code and sit in Section 1010 now. Means of egress illumination moved to Section 1008, where the 2014 version had it in Section 1006. Check the effective date of an amendment before quoting a section number on a job.

Building type decides the question. A Brooklyn brownstone may count a fire escape as its second way out, which limits how a rear door can be locked.

A Manhattan tower has pressurized stairs and re-entry doors that Chapter 10 treats on their own terms.

Review your locksmith licensing standing before bidding building work, since that is the cheap part of the job.

Turnover supplies the calls: rekeys after a sale, exit devices replaced after a failed inspection, lobby access control added by a board. Each one starts as a code question.

Egress doors and the free exit rule

Chapter 10 of the New York City Building Code is the means of egress chapter. Section 1010, Doors, Gates and Turnstiles, governs the door itself.

Egress door compliance checks

  • Openable without key, tool, or special knowledge
  • No keyed cylinder on inside of apartment door
  • No chain locks or surface bolts
  • Access-controlled doorssensor and manual release
  • Delayed egressrelease within 15 seconds, local alarm
  • Stairway doorsre-entry required in tall buildings
  • Panic hardware for occupant load 50 or more

Section 1010.1.9 covers locks and latches. Its first rule is absolute: a door on a means of egress must be openable from the side it serves without a key, tool or special knowledge.

A keyed cylinder on the inside of an apartment door fails that rule. So do chain locks and surface bolts.

When a tenant reports being locked in, the hardware is the problem.

The exceptions are narrow:

  • Access-controlled egress doors need a sensor that releases the lock as someone approaches, plus a manual release at the door.
  • Delayed egress locks must release within 15 seconds of pressure on the door and sound a local alarm.
  • Stairway doors in tall buildings need re-entry so a person who enters the stair can return to a floor.
  • Panic hardware is required on doors serving certain assembly and educational occupancies, generally those with an occupant load of 50 or more.
  • Exterior doors may be locked against entry, never against exit.

Read the current text with its New York amendments on the 2022 Construction Codes - Buildings page before trusting a national summary. Illumination and exit signage count too.

Replace a corridor door without checking the exit sign and emergency lighting circuit and an inspector can cite it.

Standard locksmith operations put that check on the ticket before the door goes back on.

Fire-rated hardware and the label

Fire door work falls under Chapter 7 of the Building Code, Fire and Smoke Protection Features. Section 716, Opening protectives, requires fire door assemblies to comply with NFPA 80, and that reference carries most of the hardware rules.

  • Confirm the door, frame, hinges and lock are all listed for the rating on the label.
  • Check that the label is legible. Removing it or painting over it fails inspection.
  • Verify holes follow the manufacturer's template. An extra hole for a hasp breaks the listing.
  • Flag any field modification beyond what NFPA 80 allows for an approved engineering evaluation.
  • Record the annual inspection and leave the records with the owner.

Fire | NIST research underpins the test methods behind those listings, so a lock with the wrong listing cannot be argued into compliance.

Ratings run 20 minutes, 45 minutes, 1 hour, 90 minutes and 3 hours depending on the wall. A 20-minute corridor door and a 3-hour shaft door take different hardware.

When a fire door needs a cylinder on the building keyway, use one listed for fire doors and keep the handing and latch throw correct.

Start with a locksmith compliance checklist that begins at the door label.

Keying hierarchies that stay legal

Hierarchy keying is standard in New York City apartment buildings: a front door key, an apartment key, staff levels and a building level for management. Rental and co-op stock keeps that work steady.

Keying hierarchy legality

  1. Front door key
  2. Apartment key
  3. Staff levels
  4. Building level for management
  5. No level may create keyed egress door
  6. Cylinder in rated door must be listed
  7. Rekeying must not change latch or closing

Code sets a floor under what a hierarchy may do. No level may create a keyed egress door. Section 1010.1.9 applies to the apartment door whoever holds the top key, so a system that traps a resident fails the code however convenient it is.

A cylinder in a rated door must be listed for that door, and rekeying may not change the latch or the door's closing action.

New York City puts lock maintenance on the owner. The Housing Maintenance Code, in Title 27 of the Administrative Code, makes building owners responsible for locks and door hardware at dwelling unit entrances. Property managers, not residents, make the call.

Fire Code Section 506 requires a key box at certain buildings so the FDNY can enter without forcing doors, and the keys inside must be current. Give the manager a written key schedule after every change.

Standards the code points to

The code does not test hardware itself. It points to standards, and that is where ANSI and BHMA come in. ANSI approves a standard; BHMA, the Builders Hardware Manufacturers Association, writes many of the hardware ones.

ANSI/BHMA standards by hardware type

Standard

A156.3
Exit devices
A156.13
Mortise locks
A156.2
Bored and preassembled locks
A156.4
Door closers
A156.5
Cylinders
A156.18
Finishes

Covers

A156.3
Chapter 10 panic hardware
A156.13
Rated corridor and apartment doors
A156.2
Residential and light commercial doors
A156.4
Self-closing fire doors
A156.5
Keyed systems and keyway control
A156.18
Hardware schedules and submittals

Where it appears

A156.3
A156.13
A156.2
A156.4
A156.5
A156.18

Two routes to code are direct. Panic hardware required under Chapter 10 must be listed to ANSI/BHMA A156.3. Hardware in a fire door assembly under Section 716 must be listed for that assembly, which routes back to the same standards through NFPA 80.

Buildings and construction | NIST research feeds the test methods behind those standards, so a listing is more than a catalog claim.

Grades matter at bid time: a Grade 1 exit device and a Grade 3 device can both carry the A156.3 mark without surviving the same traffic.

Put the grade on the submittal, and let locksmith quality control verify what arrives on site.

Permits, filings and the manager's signature

Rekeying a cylinder, replacing like-for-like hardware and cutting keys need no filing.

Permit and filing workflow

  1. Identify door function and occupancy
  2. Check egress or rated assembly, read label
  3. Match hardware to code and standard
  4. Confirm who files, get it in writing
  5. Install to manufacturer's template, photograph
  6. Hand over listings, key schedules, records

Work that alters a rated assembly, changes egress width, adds or moves a door opening, or changes occupancy does. Filings go through DOB NOW: Build, with the licensed professional of record on the plans.

Your part is supplying hardware that matches the approved drawings, with cut sheets and listings.

  1. Identify the door's function and the occupancy it serves.
  2. Check whether the door is on a means of egress or in a rated assembly, and read the label.
  3. Match the hardware to the code section and the listed standard.
  4. Confirm who filesthe manager, the architect or you. Get it in writing.
  5. Install to the manufacturer's template, then photograph the label and the work.
  6. Hand over listings, key schedules and inspection records at closeout.

Managers of federally assisted housing answer to another layer. 25red-Housing | HUD.gov / U.S. Department of Housing and Urban Development (HUD) program information covers the housing programs that carry those rules, and doors on accessible units have their own force and reach limits.

Worked example: a 1925 co-op on a Manhattan side street, twelve stories, one stair. The manager wants keyed cylinders inside apartment doors after a theft. Those doors sit on the corridor egress path, so the answer is no.

Offer a listed lockset with a thumbturn inside, an outside keyway on the building hierarchy, and a closer adjusted to swing the rated door shut. No filing, because the assembly does not change.

Photograph the label, update the key schedule, and hand over a locksmith services sheet with parts and grades.

Where the current text lives

The NYC Department of Buildings code page carries the 2022 Construction Codes and the local laws that amend them, including every section cited above. Bookmark it and check the effective date of an amendment before quoting a section on a job.

The Fire Code is a separate volume, enforced by the FDNY rather than the Buildings Department. Key box requirements and fire safety plan rules live there. ANSI and BHMA publish their standards, and NFPA publishes NFPA 80.

Licensing is its own question. Some states regulate locksmiths through a state board and some do not license at all, so confirm with your state licensing board before taking on regulated work. New York City does not license locksmiths, but the building and fire codes still bind the work.

Common questions

Do I need a permit to change a lock in NYC?

It depends on the door. A like-for-like swap on a non-rated door needs no filing. Work on a rated assembly, or anything that changes egress width or a door opening, does.

Can an apartment door have a keyed deadbolt in NYC?

Not on the inside. Section 1010.1.9 requires free egress, so most apartments get a thumbturn inside and a keyway outside on the building hierarchy.

How do I know a door is fire-rated?

Check the label on the door or the frame. Ratings run from 20 minutes to 3 hours, the label must stay legible, and the hardware has to be listed for that rating.

Does a building need a key box for the FDNY?

Some do, under Fire Code Section 506. The keys inside must match the current hierarchy, so update the box after every rekey.